Author: Valeriy Vyatkin
Printed in the U.S.A.: 1098765432
Product ISBN/ID: 978-0-9792343-0-9
IEC 61850 is continuing to gain popularity due to the multiple benefits it offers to the protection, automation and control industry. Some of them are related to the ability to describe the functionality of different intelligent electronic devices by grouping logical nodes representing functional elements in logical devices that belong to a server. However, one of the gaps in this model is the programmable scheme logic in a device and the description of distributed schemes using GOOSE messages between different devices. There are different ideas being discussed to fill this gap, such as the creation of logical nodes representing logic gates in a programmable scheme logic, or selecting IEC 61131 (standard for programmable logic controllers) to model the IED logic.
Recently a new alternative appeared on the horizon - IEC 61499. This book thus comes at the right time in order to help our industry to make a decision on how to model distributed protection and control schemes. It is a practical guide for component-based development of distributed embedded and control systems and is part of the ISA/O3neida series on distributed industrial automation.
The book is the result of the efforts of several members of O3neida - a network of networks focused on fostering distributed industrial automation based upon open standards. The leader of this writing assignment was Dr. Valeriy Vyatkin, a senior lecturer in Electrical and Computer Engineering at the University of Auckland, New Zealand, who has written many articles and papers on mechatronics and automation design.
The book contains seventeen chapters, each of which is structured as an independent study unit. This makes the book easy to use, especially by university students or busy professionals. The book explains in a practical way the concept of the IEC 61499 standard by using throughout the book an example of the control of a simple set of flashing lights. The exercises in the book are based on a Function Block Development Kit tool.
The first four chapters in the book are introductory, covering different aspects of the evolution of industrial automation, the requirements for the new generation of automation and the trends for its evolution into distributed intelligent systems.
Chapter 5 introduces the basic concepts of IEC 61499, including the key component of the model – the function block. The next chapter contains a description of the Function Block Development Kit used for the examples in the book.
The standard defines several types of function blocks described later in the book:
The modeling of applications and sub-applications, as well as devices and resources are presented in two other chapters, followed by design methodology description, including object-oriented design in industrial automation.
Each chapter in the book ends with a summary and review of questions related to its content.
Dr. Vyatkin's book provides a specific guideline on how to specify and implement a distributed system according to the IEC 61499 standard. This makes it valuable for the protection, automation and control engineer that is interested in the development, implementation and testing of distributed IEC 61850 systems. It helps us better understand the concepts of the standard and the steps that need to be followed for its use.
It should be discussed in detail within our industry in order to decide which parts of IEC 61499 can be used within the electric power systems domain.