Modernizing Teleprotection

Migrating from SONET/SDH and TDM to IP/MPLS for Reliable Protection and Control in Electric Utilities By Mauricio SUBIETA, Ph.D., CISSP, Energy CTO and Head of Technology Nokia, USA Electric...

Featured Articles

Editorial

Editorial • Opinions

Editorial – Issue 076 June 2026

Can’t live without it by Alex Apostolov, Editor-in-Chief Modern electric power systems are no longer defined solely by transformers, circuit breakers, and transmission and distribution lines. They...

Last Word

The Guru

History

History

History – Issue 076 June 2026

History of Earth Fault Detection in the 1930s, Earth Fault Compensation by Walter Schossig, Germany, and Thomas Schossig, OMICRON electronics GmbH, Austria As already the decade before the 1930s have...

News

Industry News • News

MV Protection IED

Hitachi Energy has expanded the REF650, a dedicated medium-voltage multi-function protection relay. Unlike broad-spectrum platforms, the REF650 optimizes complex protection schemes enabling value...

Industry News • News

Process Interface Device

ABB’s REX600 is a next-generation protection and control device that combines merging unit functionality, backup protection, and fault detection in a compact, DIN-rail-mounted design. It integrates...

Industry News • News

LPIT expansion modules

Siemens is advancing digital substation innovation with the introduction of LPIT expansion modules in the SIPROTEC 5 modular platform, enabling seamless process-level connectivity through low-power...

Industry Updates

IEC 61850 Update • Industry Updates

IEC 61850 Update

by Keith Gray, POWER Engineers – a member of WSP, USA IEC 61850-6-3, titled “Format of machine-processable rules for validation of IEC 61850 XML-based files”, was published in July 2025...

IEC TC57 • Industry Updates

IEC TC 57 WG 17 Update

Microgrids and planning IEC 61850 “Edition 2027” by Tom Berry, Schneider-Electric IEC TC 57 WG 17 is in charge of power system intelligent electronic device communication and associated data models...

CIGRE B5 • Industry Updates

CIGRE Study Committee B5

by Peter Bishop, Transpower NZ Ltd, New Zealand News from CIGRE Study Committee B5 Protection and Automation Preparations are now underway for the 2026 Paris Session, which will take place 23 to 28...

IEEE PSCC Update • Industry Updates

PSCC Update

by Eric Thibodeau, Hydro Quebec, Quebec, Canada The Power System Communications and Cybersecurity Committee (PSCCC) reconvened for its second meeting of 2026, jointly held with the Power Systems...